To get a quote on any of our Timing, Test and Measurement Products, click here.
Your Question


Question Type


Your E-mail
 

We respect your privacy and do not share your email address with 3rd parties. This application is used only to communicate directly with Symmetricom representatives. To view our privacy policy, click here.
Our latest product catalog is packed with the information on the precise solutions for your timing and synchronization needs. TO ACCESS, CLICK HERE.
Data Sheets. Product Information and more. To download information that could be critical to your business, TO ACCESS, CLICK HERE.
SymmTime 2008 Now Available! Download a free, convenient multi-zone desktop time utility that automatically synchronizes your system clock to any accessible NTP server. Click here.
The e-Newsletter for Timing, Test & Measurement

Your E-mail
 
We respect your privacy and do not share your email address with 3rd parties. To confirm your subscriber status, click here. To view our privacy policy, click here.
To pass along a copy of this page to anyone you would like, click here.

5120A

High Performance Phase Noise and Allan Deviation Test Set
Frequency Range: 1 – 30MHz



Get A Quote

Symmetricom’s 5120A brings a paradigm shift to the way that phase noise and Allan Deviation (ADEV) measurements are made. With the all-digital 5120A, measurements that used to be complicated and costly are now easier, more accurate, and more cost effective.

The 5120A makes accurate single sideband (SSB) phase noise and ADEV measurements at the click of a button, all at a fraction of the cost of alternative solutions. The 5120A leverages the extensive knowledge and experience obtained by Symmetricom during the development of the industry standard for ADEV measurements, the 5110A. The next generation 5120A also provides phase noise measurement accuracy down to previously impossible levels of ±1.0 dB. This combined with the best-in-industry measurement floor means that with the 5120A you can characterize even your lowest noise signals more accurately than ever before.

One Box Solution
The innovative 5120A combines sophisticated timing technologies into a single advanced instrument, which integrates all required measurement functionality into a one box solution, requiring no calibration or configuration.

Accurate Measurements Without An External Reference
Since all configuration and calibration is done by the 5120A, extremely accurate measurements can be made without a highly trained engineer having to oversee these measurements. To begin making measurements simply connect the device under test and reference (which is optional with the 5120A-01) to the 5120A and press the green Start button. Within seconds results are presented on the high resolution, real-time display.

Internal Reference Oscillator Option
The one box test solution with an integrated low noise internal reference oscillator, known as the 5120A-01, enables accurate measurements without an external reference. Previously, customers needed to provide a low noise reference at the exact test frequency which was time consuming and costly. Now, after making just one connection from the DUT to the 5120A-01, you can begin making accurate measurements. Capable of measuring down to -168 dBc/Hz, the 5120A-01 meets even the highest performance requirements.

Unparalleled Accuracy
The 5120A is the most accurate phase noise and ADEV test set in the industry. The National Institute of Standards and Technology (NIST) calibrated a sample 5120A and confirmed its accuracy to be better than ±1.0 dB, the best in the industry. At <3E-15 the 5120A’s ADEV specification at 1 second averaging time is also the industry leader.

Wide Range Measurement Capability
The 5120A’s all-digital design supports the widest range of phase noise and ADEV measurements of any commercially available product. The patented all-digital design in the 5120A enables phase noise measurements, to be without carrier suppression, which allows measurements below 0.1 mHz. This same technology makes ADEV measurements to over 300 days possible.

No Longer Must the Reference and DUT be at the Same Frequency
Unlike traditional measurement systems, the 5120A does not require that the frequency of the reference be the same as the DUT, thus allowing accurate measurements to be made on a DUT at any frequency, with a single low noise reference.

Output Options for Further Analysis
The 5120A meets the needs of applications requiring printing or further data analysis. The front panel Print button allows direct printing. When further data analysis is required, measurement data from the 5120A can be easily imported into industry standard software for frequency stability analysis, like Stable32.

Get A Quote